Please wait, content is loading

SmartAPEX wireless room control APX-TZA · APX-TZD

Smart Thermostatic Switch

One shared faceplate platform, on Z-Wave Plus. Crystal glass or Classic metal on top — the same fan-coil, valve and temperature control underneath, a different finish for the room.

Z-Wave Plus Fan-coil + valve control (AC) AC or DC back-unit
SmartAPEX Classic metal thermostat installed beside a bookshelf, woman reading in an armchair Classic metal · installed, digital display live

One electronic platform

A shared back-unit. A faceplate you choose per room.

Every thermostat is built from two parts. The back-unit is the part that goes into the wall box and decides how it’s powered, wired and which loads it drives. The faceplate is what the room sees — and it doesn’t change the control logic underneath.

Step 1 — pick the back-unit
  • AC back-unit (APX-TZA / APX-TZA010) — 3-speed fan-coil outputs, switched or continuous 0–10 VDC valve control
  • Low-voltage back-unit (APX-TZD) — 12–24 VAC/DC, four relay contacts with a shared COM
  • Every back-unit takes either an external NTC 10K probe or an external IR probe — the accessory is model-specific, not interchangeable
+
Step 2 — pick the faceplate
  • Crystal — glass finish, four fixed touch positions with interchangeable icons
  • Classic — metal finish, fixed icon layout
  • Same 86 × 86 mm mechanical footprint either way, with a digital temperature display on both

Thermostat intelligence

Six things every Z-Wave thermostat does.

Regardless of finish or back-unit, every SmartAPEX Z-Wave thermostat shares the same six capabilities.

Z-Wave Plus

Mesh platform for compatible Z-Wave networks and controllers.

Integrated temperature sensor

Onboard sensing by default; Parameter 23 switches the active reading to an external NTC 10K probe.

OTA firmware update

Updated over the air through a compatible Z-Wave controller — no faceplate removal required.

Configurable valve mode

Heat only, cool only, or heat and cool — set by configuration, alongside an adjustable Delta-T demand threshold.

Model-specific accessory

Standard models take an external NTC 10K probe; -IR models take an external IR probe instead — never both on the same unit.

Shared 86 × 86 mm faceplate

Crystal and Classic faceplates use the same mechanical platform as the SmartAPEX keypad line.

EveningEvening
Night ModeNight Mode
CookingCooking
CurtainsCurtains
22°C
Auto
APEX
4 fixed positions · icons as ordered

Configurable icon presentation

Make every touch position clear.

Personalization at your fingertips: the four Crystal icon positions are interchangeable, with alternative icons available via the SmartAPEX icon-selection sheet before ordering.

Model-specific, not interchangeable: standard models take an external NTC 10K probe; models ending in -IR take an external IR probe instead — connect only the accessory supported by the purchased model.

Lighting5 of 40+
Off
Off
On
On
Day Time
Day Time
Evening
Evening
Night Mode
Night Mode
Scenes5 of 40+
Cozy
Cozy
Light & Bright
Light & Bright
Gold Shimmer
Gold Shimmer
Reading
Reading
Cinema
Cinema
Rooms & curtains5 of 40+
Entertaining
Entertaining
Cooking
Cooking
Curtains
Curtains
Blinds
Blinds
Sheers
Sheers

Crystal’s four touch positions are fixed — only the icon inserts and diffusers at each position are interchangeable. Icon selection changes the interface, not the electrical rating.

Back-unit specifications

One visible thermostat. Two wiring approaches.

Select the back-unit from the project’s electrical requirements first, then specify the Crystal or Classic faceplate on top. AC and low-voltage versions drive different loads and have different terminals.

AC back-unitAPX-TZA / APX-TZA010

Fan-coil and valve control

Mains-powered installations driving a 3-speed fan-coil motor. TZA switches a 2-wire valve actuator; TZA010 drives a continuous 0–10 VDC valve/BMS input instead.

110–240 VAC, 50/60 HzQ1 low, Q2 medium, Q3 high fan outputsTZA: switched 2-wire valve on Q4TZA010: 0–10 VDC, 20 mA max, Q4 is N/CG / I — model-specific NTC 10K or IR probe
Low-voltage back-unitAPX-TZD

Low-voltage relay contacts

12–24 VAC/DC installations using four relay contacts with a shared common — fan-coil speeds, valve, lights or curtain loads.

12–24 VAC/DC, ~100 mA4 low-voltage relay contacts, shared COMG / I — model-specific NTC 10K or IR probeNo mains voltage on these relays

Electrical installation and load selection must follow the exact product manual and be completed by a qualified professional. Full wiring diagrams for both versions are in the manual, not reproduced here.

Installation

Prepare the thermostat and fit it correctly.

Isolate power before wiring, servicing or changing the back-unit or faceplate. Follow the exact AC or low-voltage wiring page in the manual.

1
Select the back-unitAC (APX-TZA / APX-TZA010) or low-voltage (APX-TZD) — the mechanical frame is shared, the electrical board is different.
2
Wire the back-unitFollow the exact terminal diagram for the selected version.
3
Connect the model-specific G / I accessoryStandard model: external NTC 10K sensor. Model ending in -IR: external IR probe.
4
Fit icons and diffusersCrystal model only: press each diffuser and icon insert fully into position.
5
Attach the faceplateKeep it parallel to the wall and press or release only at the corners.
6
Power-cycle onceAfter final assembly, switch power off and on once to establish the capacitive baseline.
7
Add to the Z-Wave networkPlace the controller in inclusion mode, then touch and hold Button 4 for about 4 seconds until the blue LEDs blink.

Glass faceplate kit

Icons and diffusers included

Total in box8 pieces
Faceplate removal: push / release only at the corners. Keep it parallel to the wall — do not insert a tool against the visible edge, and do not twist or flex it.

Product overview

Smart thermostatic switch at a glance.

FaceplatesCrystal glass or Classic metal, shared mechanical platform
Footprint86 × 86 mm
InteractionDigital temperature display, power, fan-speed and setpoint touch controls
TemperatureIntegrated sensor, switchable to external NTC 10K probe via Parameter 23
ProtocolSmartAPEX Z-Wave Plus, wireless
External accessoryModel-specific: NTC 10K probe (standard) or IR probe (-IR models)
Back-unitsAPX-TZA / APX-TZA010 (AC, fan-coil + valve) or APX-TZD (low-voltage relay contacts)
SpecificationConfirm exact product code, loads and accessory compatibility before ordering
SmartAPEX Classic metal thermostat installed on a wall beside a bookshelf, digital display showing 22 degrees

Product manual

Install and commission with the exact technical guide.

The manual covers Crystal and Classic faceplate preparation, AC and low-voltage back-unit wiring for fan-coil and valve applications, Z-Wave network commissioning, configuration parameters and technical limits — the authoritative source for anything electrical.