Please wait, content is loading

SmartAPEX DIN-Rail automation node APX-1616-RL · APX-2416-RL

DIN-Rail Relay Module

Multi-function relay module for lighting, curtain motor, fan-coil and valve control. Cabinet-ready, high channel density, local binding and integration-ready Ethernet / CAN-BUS workflows.

Ethernet + CAN-BUS control SDDP discovery 16 or 24 channels
SmartAPEX DIN-Rail relay module installed in a cabinet row, terminals wired 16-channel shown · installed in cabinet

Channel density

One module, two channel counts.

Same electrical ratings, same integration features on both — pick the density your panel needs.

16channelsAPX-1616-RL
SmartAPEX APX-1616-RL, 16-channel DIN-rail relay module, front view
16 A recommended per channel · 20 A internal contact capability · 250 VAC
24channelsAPX-2416-RL
SmartAPEX APX-2416-RL 24-channel DIN-rail relay module, front view, real product photo
16 A recommended per channel · 20 A internal contact capability · 250 VAC

Real product photos

SmartAPEX APX-2416-RL 24-channel relay module at an angle, RJ45 port and terminal rows
24 channels, Ethernet + CAN
SmartAPEX 24-channel relay module standing upright, push buttons and LEDs per channel
Compact DIN-rail body
SmartAPEX relay module in its kraft box with foam inserts
Shipped boxed

New in the module’s web page · Bindings map

Click a button. Click what it controls. Done.

The Bindings map shows every wall keypad, thermostat and input on the left and every relay channel, DALI address and thermostat on the right. Draw the line and the binding is made — saved on the device itself and read back to confirm. No software to install, no project file: just a browser.

  1. 1Click a button or input
  2. 2Click the channel, light or device it should control
  3. 3Press it on the wall
SmartAPEXIP Relay 24CH● Online192.168.1.20ChannelsCAN devicesBindingsSettings
WHEN · SOURCESTHEN · TARGETSKeypad · LivingGround fl.Button 1Button 2Button 3Button 4Thermostat · BedroomKey 1Key 2Key 3Key 4IP Relay 24CHPanelCh 02 · HallCh 03 · Ceiling lightCh 05 · GardenDALI GatewayPanelA04 · Spots · TcA05 · Pendant · DimG2 · Living · 3 lightsThermostat V5LivingPower & modeSaved · read back from the deviceSaved · read back from the deviceSaved · read back from the device
IN THE ROOM
Relay Ch 03 · ON
DALI G2 ·
Thermostat V5 · ON

Key 1 of the bedroom thermostat → relay channel 03 · Ceiling light. One touch switches the light.Button 2 of the living-room keypad → DALI group G2 · Living, three lights. Tap for on and off, hold to dim — the whole group follows.Button 4, held → Thermostat V5 · Power & mode. Another device can press its keys for it.

Short press · input or output changeLong press · holdDouble or triple click · releaseFull dimmer: tap on/off, hold to dim

Bindings live on each source device. Changes to an offline device are kept on the module and sent when it answers on the bus again.

Hardware highlights

Built for dense, serviceable cabinet installs.

Latching Relay Outputs

High-power latching relays per channel — hold their last state without continuous drive current.

Internal Power Supply

Built-in internal power supply — no separate external supply module needed to run the board.

Large, Convenient Terminals

Oversized wiring terminals sized for fast field wiring and easier cabinet servicing.

CAN-BUS Port Equipped

Dedicated CAN-BUS port for direct binding with keypads, thermostats and other DIN-rail nodes.

Metal Enclosure

Rigid metal body for durability and shielding in dense, high-channel-count cabinets.

Push-Button per Channel

A local push-button on every channel for manual override and testing without a controller.

SDDP Support

Built-in SDDP discovery for fast, plug-and-play commissioning on compatible systems.

Planned

Modbus TCP

Modbus TCP support is on the roadmap for a future firmware release, alongside Ethernet and CAN-BUS.

Product position

Not only a relay module — an integration-ready automation node.

The module combines relay outputs, manual override, per-channel feedback, Ethernet, CAN-BUS, SDDP and built-in web configuration into one DIN-rail platform.

Binding / Direct Control

Local CAN device-to-channel binding for keypad and automation workflows.

API for Integrators

Ethernet command, status, configuration and diagnostics for approved integrations.

SDDP Discovery

Fast discovery and easier commissioning in compatible automation systems.

Manual Override

Per-channel local push buttons and status indicators for service and testing.

Web Configuration

Built-in web setup for IP settings, channels, diagnostics and firmware workflows.

SmartAPEX CAN-BUS

Connect wall devices, keypads, thermostats, inputs and other DIN-rail modules.

Application map

One module, multiple cabinet roles.

Lighting

Incandescent, halogen, ELV/MLV, fluorescent, CFL and LED loads within derating limits.

Curtain motors

Motorized curtains and blinds using relay-pair logic where required. Motor ratings require project validation.

Fan coil

Three-speed fan coil and valve control configurations.

Valve / DC loads

Electrical valves and selected DC load control subject to voltage/current derating.

One module · three jobs

Lighting, curtains and fan coils — on the same relay module.

Every channel is set up for its job in the module’s web page: single channels for lights, interlocked pairs for curtain and blind motors, a three-speed set with its valve for a fan coil. The CAN-BUS port joins the keypads, thermostats, inputs and DALI gateways of the same project, and Ethernet takes it to the control system.

AC supply110-240 VACNetwork · EthernetWeb page, API, SDDP discoveryControl4,control systemsSmartAPEX IP Relay 16 / 24APX-1616-RL · APX-2416-RL16 A PER CHANNEL · 250 VACMANUAL OVERRIDEF1ETHERNETCAN-BUS portOther APEX devicesKeypads, thermostats,inputs, DALI, other modulesCAN H LLightingAny channel, any load within deratinge.g. CH 1-8 · on / off, timersCurtains & blindsA channel pair, interlockedOpenClosenever bothe.g. CH 9-10 · open / close pairFan coilThree speeds and the valveLOWMEDHIGHe.g. CH 11-14 · L / M / H + valveAC lineCAN-BUSRelay outputsEthernetAC supply110-240 VAC · fuse F1SmartAPEX IP Relay 16 / 24APX-1616-RL · APX-2416-RL16 A PER CHANNEL · 250 VACLightinge.g. CH 1-8 · on / off, timersCurtains & blindse.g. CH 9-10 · interlocked pairOpen / Close,never bothFan coile.g. CH 11-14 · L / M / H + valveLOWMEDHIGHCAN-BUS portKeypads, thermostats, inputs, DALIEthernetweb page, API, SDDP → control systemACCANOutputsEthernet

Channel numbers are an example. Motor and valve ratings need project validation; for wiring, follow the installer manual.

Specifications

Technical product specifications.

Electrical ratings are separated between product-level module limits and internal contact capability.

Model numberAPX-1616-RL (16-channel) or APX-2416-RL (24-channel)
SeriesG3 Series, SDDP support, AC power supply
Supply voltage100–240 VAC, 50/60 Hz
Power consumption< 3 W
Control communicationEthernet, CAN-BUS
Output channels16 or 24 relay outputs, depending on model
Output load ratingRecommended module output rating: 16 A resistive per channel @ 250 VAC. Internal relay contact capability: up to 20 A resistive @ 250 VAC. Total simultaneous load is limited by wiring, terminal rating and PCB thermal design.
Impulse withstandRelay contact short-circuit impulse withstand: up to 750 A for 10 ms. This is not a continuous or operating current rating.
Supported load typesResistive loads and selected lighting drivers within rating. LED drivers, transformers, motors and DC loads require derating and project validation.
Operating temperature-10 to 60 °C
Humidity5% to 95% non-condensing
Weight1 kg

Important rating note. Do not interpret 750 A / 10 ms as operating current or guaranteed switching current — it is an impulse withstand value.

The recommended published module output rating remains 16 A resistive per channel unless a higher product-level rating is validated by thermal and safety testing.

Total simultaneous load must be limited by installation wiring, terminal rating, PCB thermal design, enclosure temperature and upstream protection.

LED status

Commissioning indicators.

LEDStateMeaning
LKRedEthernet not connected.
LKGreenEthernet connected, acquiring DHCP IP.
LKYellowEthernet connected, acquired DHCP IP, and connected to the host.
LKBlueEthernet connected, using STATIC IP.
LKPurpleEthernet connected, using STATIC IP, and connected to the host.
DActivityTransmission and reception of messages over Ethernet or CAN-BUS.
PWFast blinkNot connected to network.
PWSlow blinkEthernet cable connected, obtaining IP address.
PWVery slow blinkValid IP address and network connected.

Local functions

Push-button commissioning and recovery.

  • SDDP IdentifyPress and hold the PRG button for 4 seconds to initiate SDDP identification.
  • Factory ResetPress and hold the PRG button for 12 seconds until the PW LED starts blinking fast. Release to reset to factory settings.
  • Manual Static IPPress and hold the highest-numbered channel push button (16 or 24, depending on model) for about 15 seconds. When PW blinks rapidly, release — the module restarts at 192.168.1.150.

Binding and integration

Designed for panels, integrators and real projects.

Use the module as an Ethernet-connected cabinet controller, a SmartAPEX CAN-BUS node, or a bridge between wall devices and relay outputs.

Binding / Direct Connection

Local SmartAPEX device-to-device control can bind compatible CAN devices to relay targets. Typical use: keypad/input action → relay channel or relay group, with state feedback where supported. Binding capacity and supported object types depend on firmware version.

API for Integrators

Local API available for approved integrators. Capabilities include channel control, status monitoring, configuration access, diagnostics and binding workflows where supported. Final endpoint list depends on firmware version.

Browse to the module’s current IP address to open the built-in web configuration page. Network settings can be set for DHCP or static IP with the required IP, gateway and subnet parameters — the same page holds channel configuration, the Bindings map, CAN devices, firmware update and diagnostics.

Ethernet / TCP-IP — web configuration, controller integration, API CAN-BUS — SmartAPEX local devices and DIN-rail networking SDDP — device discovery in compatible automation ecosystems

Product manual

Install and commission with the exact technical guide.

Each channel count has its own manual covering specifications, LED status, PRG functions, binding, integration and installation wiring — the authoritative source for anything electrical.

Local firmware updates

Updated on site, without the internet.

  • No internet at the module

    The installer opens the module's update page in a browser. The browser fetches the firmware and sends it to the module over the local network.

  • One button says whether you are current

    One button, Check for updates, tells you whether the module is current.

  • Gateway updates reach the CAN devices

    Updating a gateway also updates the CAN devices behind it.

Applies to Relay 16, Relay 24, MINI IP Gateway and DALI Gateway, and to the CAN devices behind a gateway.