Please wait, content is loading

SmartAPEX DIN-Rail automation node APX-DG

DALI Gateway

DIN-rail DALI master for Ethernet-based lighting control. Commission DT6 and DT8 gear from a web interface, then bind SmartAPEX CAN-BUS devices to DALI addresses, groups and scenes.

Ethernet + CAN-BUS + DALI DT6 and DT8 commissioning 64 addresses · 16 groups · 16 scenes
SmartAPEX DALI Gateway APX-DG, DIN-rail DALI-2 / CAN-BUS gateway with display and Ethernet port, real product photo Real product photo

Real product photos

SmartAPEX DALI Gateway APX-DG front panel with LED display, SET and MENU keys
Front panel
SmartAPEX DALI Gateway APX-DG at an angle, display and RJ45 Ethernet port
Display and Ethernet
SmartAPEX DALI Gateway APX-DG red aluminium body with product label: CAN-BUS, DALI2, Ethernet
Aluminium heat-sink body
64

DALI short addresses

16

DALI groups

16

DALI scenes

250 mA

Integrated DALI supply

New in the module’s web page · Bindings map

Click a button. Click what it controls. Done.

The Bindings map shows every wall keypad, thermostat and input on the left and every relay channel, DALI address and thermostat on the right. Draw the line and the binding is made — saved on the device itself and read back to confirm. No software to install, no project file: just a browser.

  1. 1Click a button or input
  2. 2Click the channel, light or device it should control
  3. 3Press it on the wall
SmartAPEXDALI Gateway● Online192.168.1.20ChannelsCAN devicesBindingsSettings
WHEN · SOURCESTHEN · TARGETSKeypad · LivingGround fl.Button 1Button 2Button 3Button 4Thermostat · BedroomKey 1Key 2Key 3Key 4IP Relay 24CHPanelCh 02 · HallCh 03 · Ceiling lightCh 05 · GardenDALI GatewayPanelA04 · Spots · TcA05 · Pendant · DimG2 · Living · 3 lightsThermostat V5LivingPower & modeSaved · read back from the deviceSaved · read back from the deviceSaved · read back from the device
IN THE ROOM
DALI G2 ·
Relay Ch 03 · ON
Thermostat V5 · ON

Button 2 of the living-room keypad → DALI group G2 · Living, three lights. Tap for on and off, hold to dim — the whole group follows.Key 1 of the bedroom thermostat → relay channel 03 · Ceiling light. One touch switches the light.Button 4, held → Thermostat V5 · Power & mode. Another device can press its keys for it.

Short press · input or output changeLong press · holdDouble or triple click · releaseFull dimmer: tap on/off, hold to dim

Bindings live on each source device. Changes to an offline device are kept on the module and sent when it answers on the bus again.

Installation-ready highlights

Everything an installer needs for one DALI line.

DALI Commissioning

Read-only rescan, safe addressing of unaddressed gear and explicit full readdressing.

Web Configuration

Network setup, device labels, groups, scenes, diagnostics and firmware workflows.

SmartAPEX CAN Bus

Discover compatible CAN devices and bind them to DALI addresses, groups or scenes.

DT8 Color Control

DT6 plus DT8 tunable white, XY, RGB, RGBW and RGBWAF control where supported.

Product overview

A compact DALI master for Ethernet-based lighting control.

Commissioning, device control, groups, scenes, network settings and firmware maintenance all run from one web interface.

DALI Master

Up to 64 short addresses, 16 groups and 16 scenes with DT6 and DT8 support.

Integration

Ethernet web interface plus SmartAPEX CAN device discovery, configuration and bindings.

DIN-Rail

Designed for cabinet installation. Follow the approved wiring drawing and local electrical rules.

System architecture

DALI line, CAN bus and Ethernet meet at one gateway.

The gateway connects the DALI lighting line to Ethernet and CAN bus. The web interface is used for commissioning, device control, groups, scenes, network settings and firmware maintenance.

Terminal groupFunction
L / NAC line supply
H / LCAN bus high / low
DA / DADALI bus pair

Installation note. Terminal names and order must be verified against the approved hardware drawing and product label before energising.

Safety before power-up

  • Installation and commissioning must be performed by a qualified installer.
  • Isolate power before wiring or changing DALI, CAN or mains connections.
  • Keep the gateway and DALI gear powered during addressing and firmware update.
  • Do not disconnect the DALI line while commissioning is active.
AC supply110-240 VACSmartAPEX DALI GatewayAPX-DG · DIN railDALI SUPPLY 250 mA BUILT INL NH LDA DAF1Wall devices on CAN-BUSKeypads, thermostats, inputs, relaysDaisy-chainedH / L, one busDALI lineDT6 / DT8 drivers · up to 64 addressesDALI DRIVERDT8 · RGBWDALI DRIVERDT8 · RGBWDALI DRIVERDT8 · RGBWLED drivers take their own 12/24 V supplyNetworkRouter / switch · control systemWeb page,Control4, APEXETHERNET RJ45AC lineCAN-BUSDALIEthernetAC supply110-240 VAC · fuse F1SmartAPEX DALI GatewayAPX-DG · DIN railDALI SUPPLY 250 mA BUILT INWall devices on CAN-BUSKeypads, thermostats, inputs, relaysDaisy-chained, H / LDALI lineDT6 / DT8 drivers · up to 64 addressesDALI DRIVERDT8 · RGBWDALI DRIVERDT8 · RGBWDALI DRIVERDT8 · RGBWNetworkEthernet RJ45 → router / control systemACCANDALIEthernet
Typical SmartAPEX DALI / CAN installation — reference topology from the installer manual. For wiring, always follow the manual’s approved hardware drawing, not this diagram.

Gateway status indicators

Read link, traffic and power state at a glance.

LK reports Ethernet link and host state. D flashes on message traffic. PW shows network acquisition progress through its blink rate.

LEDStateMeaning
LKRedEthernet not connected.
LKGreenEthernet connected; acquiring a DHCP IP address.
LKYellowEthernet connected, DHCP IP acquired and connected to the host.
LKBlueEthernet connected and using a static IP address.
LKPurpleEthernet connected, using a static IP address and connected to the host.
DActivityTransmission and reception of messages via Ethernet or CAN bus.
PWFast blinkingNot connected to the network.
PWSlow blinkingEthernet cable connected; attempting to obtain an IP address.
PWVery slow blinkingModule connected to the network with a valid IP address.

Diagnostic reading. If PW is fast blinking, check the Ethernet cable and link. If it is slow blinking, wait for DHCP. Very slow blinking means a valid network address has been obtained.

DALI commissioning

Choose the least destructive action.

Match the action to the installation state — from a safe read-only scan to a full address rebuild.

Rescan Existing Devices

Read-only scan of DALI short addresses 0 through 63. It does not send INITIALISE, RANDOMISE or PROGRAM SHORT ADDRESS commands.

Address Unaddressed

Commission only gear without a valid short address. Existing valid short addresses are preserved.

Full Readdress

Clears and rebuilds the DALI short-address plan. Use only for a new line or an intentionally discarded address plan.

Cancel Addressing

Requests a controlled stop. Wait for the gateway to report canceled or failed before taking further action.

Existing lineRescan
New gearAddress Unaddressed
New lineFull Readdress

Destructive action. Full Readdress can change every physical short address on the line. Back up labels, group assignments, scenes and integration settings first.

Physical address maintenance

  • Delete removes a row from the gateway’s local list only — it does not clear the physical driver address.
  • Clear Physical Address changes the physical DALI gear and accepts an address from 0 through 63. After a successful clear, run Address Unaddressed to assign a new one.
  • A duplicate-address warning can indicate overlapping DALI replies or a bus collision — isolate sections and rescan.
FeatureRangeUse
Groups0–15Add or remove devices; labels are gateway metadata.
Scenes0–15Store and recall levels or DT8 values for a device or group.
ReportLine-wide viewReview memberships and stored scene information.

Control & integration

Local control today, distributed control over CAN bus.

Use the web interface for local commissioning and connect compatible SmartAPEX CAN devices for distributed control.

Control areaAvailable controlNotes
All DevicesBroadcast controlApplies the selected action across the DALI line.
Individual deviceOn, off, levelTargets one DALI short address.
DT8 colourTC, XY, RGB, RGBW, RGBWAFShown according to the reported device type.
Groups / scenesMembership, store, recallUse after the addressing plan is stable.
StartupLast state / normalVerify on each approved driver model.

Preserve previous state. When Last state is selected, the gateway programs and verifies SYSTEM FAILURE LEVEL = FF and POWER ON LEVEL = FF. The physical DALI driver is responsible for preserve behavior — the gateway does not replay a cached brightness level during recovery. Test the gateway and driver mains power-cycle separately, and repeat for each approved driver model.

Discover

Search CAN Devices for a full discovery, then use Refresh to update the cached state.

Configure

Review Overview and open Configuration only for fields supported by the device firmware.

Bind

Create documented bindings to local DALI addresses, groups or scenes and verify after restart.

Ethernet — web configuration, network settings, firmware CAN-BUS — SmartAPEX device discovery and bindings DALI DT6 / DT8 — up to 64 addresses, 16 groups, 16 scenes

Specifications

Technical product specifications.

Model numberAPX-DG
Product typeDALI Gateway
Supported DALIDT6, DT8
ControlEthernet, CAN bus, DALI
DALI supply250 mA, integrated — no separate DALI power supply required
Power requirement110–240 VAC
Power consumption< 5 W
Operating temperature-10 to 60 °C
Humidity5% to 95% non-condensing
Weight0.5 kg

Initial installation

Wire it, power it, then commission from the browser.

Complete the physical installation first, then use the web interface to commission the DALI line.

1
Inspect wiringComplete and inspect mains, DALI, CAN and Ethernet wiring before applying power.
2
Power the linePower the gateway and all DALI gear that will be discovered or addressed.
3
Find the gatewayUse the router DHCP list or SmartAPEX Finder to identify the current IP address.
4
Open the web UIBrowse to the gateway’s IP address and sign in with the current credentials.
5
CommissionUse Address Unaddressed for additions, or Full Readdress only for a deliberate rebuild.
6
Verify and labelConfirm the count, resolve offline devices, label addresses, then configure groups and scenes.

Network access defaults

ItemFactory defaultInstaller action
Address modeDHCP enabledRead the assigned address from the router or Finder.
Static IP192.168.1.150Use only when a static configuration is intentionally selected.
Netmask255.255.255.0Match the site network plan.
Gateway192.168.1.1Match the site router when static IP is used.
Credentialsadmin / adminChange the default password after first login.

Product manual

Install and commission with the exact technical guide.

Covers specifications, LED status, DALI commissioning actions, control and integration, and installation wiring — the authoritative source for anything electrical, plus diagnostics and site-handover reference for installers.

Local firmware updates

Updated on site, without the internet.

  • No internet at the module

    The installer opens the module's update page in a browser. The browser fetches the firmware and sends it to the module over the local network.

  • One button says whether you are current

    One button, Check for updates, tells you whether the module is current.

  • Gateway updates reach the CAN devices

    Updating a gateway also updates the CAN devices behind it.

Applies to Relay 16, Relay 24, MINI IP Gateway and DALI Gateway, and to the CAN devices behind a gateway.